Keywords: Environmental protection equipment | Air purifier | Testing Equipment | Chemicals | Valve series
Products
Total phosphorus Online Automatic monitor
Total phosphorus Online Automatic monitor

Total phosphorus is the sum of water particles and dissolved organic phosphorus and inorganic phosphorus, Total phosphorus reflect the extent of water contamination by phosphorus. An increase in the content of phosphorus in water can cause eutrophication, resulting in blooms or red tide occurred, seriously affecting water quality. 

Features: 
Instruments complete digestion than one color, simple and reliable structure, reducing potential errors. 
Imported modified PTFE transparent hose, diameter greater than 1.5mm, reducing the chances of blockage of water-like particles. 
Can automatically clean sampling pipes to prevent algae or biofilm formation. 
Error reset and power off the call, the instrument automatically discharge the residual reactants instrument automatically return to work status. 
Low failure rate, maintenance, less reagent consumption. 
Intelligent self-diagnostics, alarm, equipment management and maintenance very convenient. 
Imported PLC control devices to reduce environmental interference and equipment failure. 
Multi-channel valve, strong corrosion resistance, long life, safe and reliable.

Applications: 
Total phosphorus adapted in 0 ~ 50mg / L range wastewater. Most common ions do not interfere with the determination, but for some samples contain large amounts of organic matter, the measurement results may be low. 
Laboratory and field testing of water quality analysis Online Fast rivers, lakes and reservoirs, groundwater quality monitoring Online Online waterworks water quality monitoring of industrial effluent in municipal sewage Online Monitoring Water treatment plant Water Online Monitoring & Exports

Technical Parameters: 
Model: DH312P1 
Methods based on: HJ 593-2010 "Water quality - Determination of elemental phosphorus - phosphorus molybdenum blue spectrophotometry" 
Measuring range: 0 ~ 50mg / L Total phosphorus 
Accuracy: Indication error ≤ ± 10% 
Repeatability error: ≤ ± 10% 
Measuring cycle: the minimum measurement period of 40min, according to the actual water samples can be arbitrarily modified 5 ~ 120min digestion time. 
Sampling period: time interval (20 ~ 9999min adjustable) and the whole point measurement mode correction: timing instrument sensitivity and zero calibration calibration period: 1 to 99 days at any arbitrary time interval adjustable maintenance cycle: Usually once a month, every views about 30min 
Analog output: 4 ~ 20mA 
Signal interface: RS232 / RS485 
Environmental requirements: Recommended temperature + 5 ~ 28 ℃; humidity ≤90% (non-condensing) 
The actual water samples Contrast: Error ≤ ± 10% 
MTBF: ≥720h / second Dimensions Height: 1420 × width 500 × depth 400 (mm) 
Power: AC220 ± 10% V, 50 ± 10% Hz, 5A 
Other: abnormal alarm and power without losing data; touch-screen display and command input; abnormal reset and power off the call, the instrument automatically discharge the residual reactants is automatically return to work status

 
点击这里给我发消息