Industrial Residual chlorine Online analyzer is a new chlorine analyzer, this table has a high degree of intelligence and flexibility, which can measure free chlorine, hypochlorous acid, pH, temperature, widely used in electricity, water, medicine, chemical industry , food and other industries, water for chlorine and pH were measured continuously.
Features:
Wide range and low detection limit
Selective membrane sensor
With pH compensation with thermistor temperature compensation
Built-in flow control device
Little maintenance, simple installation, easy maintenance
Technical Parameters:
Measuring range: Chlorine: 0 ~ 20.00mg / L, Resolution 0.01mg / L
HOCL: 0 ~ 10.00mg / L, the resolution of 0.01mg / L
pH value: 0 ~ 14.00pH, resolution 0.01pH
Temperature: 0 ~ 99.9 ℃, 0.1 ℃ resolution
Accuracy: Chlorine: better than ± 1% or ± 0.01mg / L, whichever is greater
HOCL: better than ± 1% or ± 0.01mg / L, whichever is greater
pH value: better than ± 0.01pH
Temperature: better than ± 0.5 ℃ (0 ~ 60.0 ℃)
Minimum detectable: 0.01mg / L HOCL
Working environment: Temperature 0 ~ 45 ℃ / Relative humidity ≤85%
Analog output: 4 ~ 20mA, load 750Ω (optional HOCL, FAC, PH, one T)
Switching output: two relay switches (optional HOCL, FAC, PH, one T)
Digital interface: RS485 (ModBus protocol)
Chlorine Sensors
Response Time: Less than 90% 2min, 95% less than 5min (room temperature)
Temperature range: measuring 2 ~ 45 ℃
Minimum flow rate: 200 ~ 250mL / min, flow-through traffic is not less than 30L / h
PH range: 4 ~ 8.2pH
Pressure range: 0 ~ 1bar
Temperature compensation: Thermistor
Electrode cable: 3m high impedance low noise shielded cable
Electrode material: 316L stainless steel shell, POM membrane cap, PTFE membrane
Interval: Usually replaced every six months membrane and electro-hydraulic (determined by media)
Applications
Suitable for drinking water, industrial process water disinfection process hypochlorous acid (HOCL) residual chlorine concentration Online monitoring can also be used in swimming pools and other places need to measure chlorine concentration.
Features
The range is very wide and precise, using constant voltage electrode
Menu design using object-oriented menu design, simple and clear
Instrument case multi-screen display, there are three ways, different aspects of the user's requirements for display
Chlorine residual chlorine zero calibration provides calibration and slope calibration, menu design clarity
Digital clock provides timing function, with temperature compensation
Low alarm hardware isolation, each channel can be arbitrarily chosen measurement parameters, hysteresis can be preset
Current output using isolation technology, anti-jamming capability, you can set upper and lower limits
Technical Parameters
Measuring range: Chlorine: 0 ~ 20mg / L, the resolution of 0.01mg / L
Temperature: 0 ~ 99.9 ℃, 0.1 ℃ resolution
Accuracy: Chlorine: better than ± 2% or ± 0.02mg / L, whichever is greater
Temperature: better than ± 0.5 ℃ (0 ~ 60 ℃)
Minimum detectable: 0.01mg / L
Repeatability: ± 0.01mg / L chlorine
Analog output: 4 ~ 20mA, 750Ω load
Switching output: relay alarm, arbitrarily set the amount of hysteresis, capacity AC220V, 5A;
Can independently select the corresponding measurement parameters (FAC, T)
Value Interface: RS485 communication, partially compatible Modbus protocol (optional)
Working environment: temperature 0 ~ 60 ℃ Relative humidity <85%
Power supply: AC220V ± 10%, power ≤10W
Protection: IP65
Chlorine Sensors
Measuring range: 0 ~ 2ppm, 2 ~ 20ppm, 0 ~ 200ppm
Electrode: glass bulb, inside platinum, glass body
Reference electrode: gel with annular junction
Electrode cable: 3m high impedance low noise shielded cable
Working pressure: 10bar at 20 ℃
Applications
System applicable to the water industry, filling industry, chlorine, chlorine dioxide or dissolved ozone measurements.
Selection coding CLSS6500
Host computer | sensor |
M1: Wall-mounted | CR2200: ORP law |
F1: panel mounted | CM3300: Membrane method |
E1: Cabinet |
Example: CLSS6500F1-CR2200: panel mounted chlorine host, ORP sensor method.